A few photographs of various parts of the treehouse described in the previous post.
This is a shot of the cantileverd deck edge, with the new 2x8 end beam in place. This was the one that had to be cut at approx 65 degrees, and spans the three deck beams. Lots of fun chalking, guesstimating, cutting, and fitting to get this baby in!
A view from underneath, showing one of the pair of main beams bolted through the tree, two of the deck beams running perpendicular to the main beams (at the extreme left and right of the photograph), and some of the 2x6 floor joists which run in the same direction as the main beams. Note the joist hanger and crossjoist which had to be installed to support the floor close to the tree itself.
Finally, a close up of one of the two sheet metal sliders fastened under the main beams that rest on top of the wooden bracket on the smaller tree. The main beams will creep back and forth across the bracket when the wind picks up, and these metal strips will hopefully reduce the friction and wear on both the beams and the bracket.